Your Professional Metallic Tube Variable-Area Flowmeters Supplier

 

 

KIO is a professional manufacturer of solenoid valve and flow instruments. Starting with flow meters since 1995, we are now specialized in provide on-off control of various fluids, such as water, air, steam, oil, gas, hot water, etc.

 

 
 
Why Choose Us

 

Quality Control

We have high-precision equipment to strictly control product quality.

 

Our Service

We have experienced staff members are always available to discuss your requirements and ensure full customer satisfaction.

Factory Strength

Covering an area of 15000 square meters, we now have over 100 employees, an annual sales figure that exceeds USD 3800000 and are currently exporting 40% of our production worldwide.

Foreign trade market

As a result of our high quality products and outstanding customer service, we have gained a global sales network reaching Southeast Asia, Central America,Northern Europe.

 

 

Metallic Tube Variable-Area Flowmeters Specifications

 

Aperture Diameter

DN15, DN25, DN50, DN80, DN100, DN150
(Other diameters, need consult us and customized)

Flow Range

Liquid: 1.0 ~ 150000L /h gas: 0.05 ~ 3000m3/h

Ratio Range

10∶1, 20∶1 (Special)

Viscosity of medium

DN15: < 5mPa. S / DN25: < 250mPa. S
DN50 ~ DN150: < 300mPa.S

Flange

GB/T9119-2000standard carbon steel
(Stainless steel optional),Other standards can be customized

Rated Pressure Grade

DN15, DN25, DN50:4.0MPa (Max 20MPa)
DN80, DN100, DN150:1.6mpa
(Max:DN80:10MPa;DN100:6.4 MPa;6:4.0 MPa)

Tube and Float Material

Default Stainless steel 304, SS316L, Hastelloy (HB and HC), Titanium can be customized,

PTFE lining can customized Can

Ingress Protection

IP65 for Shell

Accuracy Grade

1.5 grade, 1.0 grade (Special customized)

Medium Temperature

Standard -30ºC ~ +120ºC, high temperature: 120ºC ~ 350ºC

Ambient temperature

-40ºC ~ 120ºC Remote: -30ºC ~ 60ºC

Storage condition

-40ºC ~ 85ºC Humidity: ≤85%

Supply Voltage

24VDC (12 ~ 36VDC)

Output

4 ~ 20mADC (two wire), HART protocol can be attached;
Alarm dry contact signal

 

Key Features

 

It is suitable for measuring the flow rate of medium with small diameter and low velocity.

Reliable operation, small amount of maintenance, long life.

Requirements for straight section are not high.

Wider range ratio of 10:1.

Double-line LIQUID crystal display, field instantaneous/cumulative flow display.

There is a keyboard on the indicator for easy operation and setting.

All-metal structure, suitable for high temperature, high pressure and strong corrosive medium.

Non-contact magnetic coupling transmission.

Can be used in inflammable and explosive dangerous occasions.

Optional DC power supply or battery power supply mode.

With data recovery, data backup and power down protection functions.

Multi-parameter calibration function.

 

Principle structure

As the fluid upward in the tube, the float moves upward to a certain positon where the lifting force and the gravitational force Are balanced, at the moment, the circulation area between the float and the orifice is kept fixed.The circulation area is Proportinal to the height of the float, it means the height of the float represent the volumetric flowrate. When the float

 

Moves up and down, it transmits its positional to the indicator outside in form of magnetic-coupling, so make the needle of the Indicator follows the movement of the float, and by using the cam board to show the value of flowrate linearly on the indicator

 

 
 
Main components
productcate-292-341

Tapered Tube

The metal tube is tapered, meaning it gradually widens from bottom to top.This shape allows the float to stabilize at different levels based on the flow rate, as the increased area at the top fits higher flow rates.

productcate-292-341

Float

The float is often made of a corrosion-resistant material like stainless steel. It's carefully designed to offer stable equilibrium within the tube, moving up and down freely in response to changes in flow rate.

Metallic Tube Variable-Area Flowmeters

Magnetic Coupling

Many metal tube rotameters use a magnetic coupling to transmit the float position to an external indicator, eliminating the need for a transparent tube.

productcate-292-341

Indicator Mechanism

The external scale or indicator provides the flow reading. It can be analog or digital, depending on the specific rotameter model.

 

 

Applications
 

Oil & gas industry

In oil and gas refineries, metallic tube variable-area flowmeters monitor the flow of crude oil, natural gas, and other hydrocarbons.their power to handle high pressures makes them suitable for pipelines and wellheads.

Chemical processing

Metallic tube variable-area flowmeters, resistant to corrosion and capable of withstanding challenging conditions, are frequently used to monitor the flow of chemicals and process liquids.

Waste water treatment

Metallic tube variable-area flowmeters are used in wastewater treatment facilities to measure the flow of water and chemicals for disinfection and ph adjustment processes.

Pharmaceutical industry

In controlled environments, metallic tube variable-area flowmeters help monitor the flow of solvents, water, and other process fluids essential to pharmaceutical production.

 

Our Certificates

 

productcate-1-1
productcate-1200-535
productcate-1-1
productcate-1-1
productcate-1200-535
productcate-1-1

 

FAQ

 

Q: Are you a manufacturer or a trading company?

A: We are a leading manufacturer of all pneumatic products. Welcome to visit our factory at any time.

Q: What's the payment term?

A: T/T, MasterCard, VISA, E-Checking, Boleto, Pay Later.

Q: How about the delivery time ?

A: 1-3 days for normal models. For big orders, it takes about 10-15 days.

Q: What is the standard of package?

A: Export standard package or special package according to customers' requirement.

Q: What kind of product quality does your factory offer?

A: We are top 3 supplier in Chinese market. We offer top quality to our clients.

Q: What is the principle of metal tube flow meter?

A: Metal tube rotameters work based on the principle of variable area. It consists of a tapered tube, typically made of steel with a float. The fluid in the metal tube raises the float in the tapered tube increasing the area of passage of fluid.

Q: What is the difference between metal tube and glass tube rotameter?

A: Unlike glass tube rotameters, which are more common for lower pressures and clear visibility, metal tube rotameters are typically used in environments where the fluid is turbid, high-pressure, or chemically reactive.

Q: What is the rule of thumb for flow meter installation?

A: Note the intended direction of the flow as indicated by an arrow on top of the Flow Meter. There must be free, unrestricted pipe of the same size as the Flow Meter, with a length of at least 10 times the flow meter size upstream, and 5 times the flow meter size downstream of the Flow Meter tee.

Q: What is the minimum flow rate for a magnetic flow meter?

A: The electromagnetic flow meter can be used for continuous measurement or for batching and dosing applications. The MAG-VIEW™ series operates on the magnetic inductive principle and is therefore suitable for electrically water and conductive liquids with a minimum conductivity of 20 or 50 μS/cm.

We're professional metallic tube variable-area flowmeters manufacturers and suppliers in China, specialized in providing high quality products and service. We warmly welcome you to buy or wholesale high-grade metallic tube variable-area flowmeters for sale here from our factory.

Metallic Tube Flowmeters, Metallic Tube Variable Area Flowmeters